Each column is one deployment. Matching context does not establish equivalent physical hosts.Benchmark medians · network trials linked separately
PerformanceReviewed data
Vultr4 vCPU · 7.7 GiB
DigitalOcean4 vCPU · 7.8 GiB
01 /
CPU performance
sysbench prime events · max prime 20,000 · gzip level 6 · higher is better
MetricVultr voc-c-4c-8gb-75s-amdDigitalOcean c-4
Single thread
1,345events/s
90% of 1,500
497.5events/s
33% of 1,500
All 4 vCPUs
5,348events/s
89% of 6,000
1,544events/s
26% of 6,000
gzip compression
181.5MiB/s
73% of 250
241.3MiB/s
97% of 250
Identical thread counts and test settings. Bars use a common scale within each row.
02 /
Memory bandwidth
sysbench · 256 MiB block · one thread · higher is better
MetricVultr voc-c-4c-8gb-75s-amdDigitalOcean c-4
Read
14,876MiB/s
99% of 15,000
8,331MiB/s
56% of 15,000
Write
14,825MiB/s
99% of 15,000
8,450MiB/s
56% of 15,000
Bars share one scale across both rows. A memory copy workload is not part of this profile.
PerformanceReviewed data
VultrBangalore, IN
DigitalOceanBangalore, IN
03 /
Disk performance
fio · direct I/O · 1 MiB / QD32 sequential · 4 KiB / QD32 random
MetricVultr voc-c-4c-8gb-75s-amdDigitalOcean c-4
Sequential read
5,022MB/s
9,489MB/s
Sequential write
2,413MB/s
1,670MB/s
Random read
98,211IOPS
151,801IOPS
Random write
85,453IOPS
135,456IOPS
Random read p95
436.2µs
280.6µs
Random write p95
514.0µs
329.7µs
Throughput and IOPS: higher is better. Latency: lower is better. Mixed 70/30 runs and p50/p99 latency are in each full report.
04 /
Network performance
LibreSpeed CLI · HTTPS / IPv4 · three streams · 10 seconds per direction
MetricVultr voc-c-4c-8gb-75s-amdDigitalOcean c-4
Frankfurt · source
Network reportSeparate VM test · 17 Oct 2026, 17:58 UTCBangalore, IN · Frankfurt, Germany (Clouvider)
Network reportSeparate VM test · 17 Oct 2026, 18:15 UTCBangalore, IN · Frankfurt, Germany (Clouvider)
Frankfurt · Download
264.9Mbit/s
168.6Mbit/s
Frankfurt · Upload
75.2Mbit/s
140.8Mbit/s
Frankfurt · HTTP latency
177.4ms
133.4ms
Frankfurt · HTTP jitter
2.16ms
0.10ms
New York · source
Network reportSeparate VM test · 17 Oct 2026, 17:58 UTCBangalore, IN · New York, United States (2) (Clouvider)
Network reportSeparate VM test · 17 Oct 2026, 18:15 UTCBangalore, IN · New York, United States (2) (Clouvider)
New York · Download
164.2Mbit/s
296.7Mbit/s
New York · Upload
39.4Mbit/s
91.0Mbit/s
New York · HTTP latency
298.9ms
214.4ms
New York · HTTP jitter
0.32ms
0.09ms
Each network source is a linked same-VM supplement when available, otherwise a later test on a separate VM matching provider, plan, recorded region and resources. Frankfurt and New York are separate paths, with one trial per direction. HTTP latency and jitter are recorded; packet loss is not measured. Routes and times affect results; these trials do not establish maximum link capacity or long-term consistency.